Planning study

A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note.

Paddick I

View Source Under Review

DoseLab summary

Technical note reviewing earlier radiosurgery conformity measures, showing that they can give false perfect scores, and deriving a new index that does not. The abstract was read in Europe PMC; the index's formula is checked as described in Menon 2018. Citation checked against Crossref.

Why this is useful

The origin of the Paddick conformity index — the measure that penalizes both missed target and irradiated normal tissue, so it cannot give a false perfect score.

Reference details

Title
A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note.
Authors / organization
Paddick I
Publication / protocol
J Neurosurg. 2000;93 Suppl 3:219–222
Version
Pending verification
Year
2000
DOI
10.3171/jns.2000.93.supplement_3.0219
Disease sites
CNS / Brain
Topics
Plan Evaluation, SRS, Conformity
Fractionation context
Single fraction (radiosurgery)
Last reviewed by DoseLab
Pending verification